Purelab Chorus series

ELGA Labwater from UK is an integral part of Veolia Water Technologies, the world leader in water treatment.

ELGA specializes in delivering water purification systems for research, diagnostic, clinical and healthcare environments. ELGA has 75 years experience in water purification technologies. ELGA’s water purification system has unique features like continuous real-time water quality monitoring, recirculation of purified water stored in tanks, customizable audible and visual alarms etc.

Key Features:

Key Features:

Chorus 1 Life Science | Analytical Research | General Science

Chorus 1 Complete Variants: 10l/hr & 20l/hr with or without boost pump

Chorus 2+ (RO/EDI/UV) Variants: 10l/hr & 20l/hr with or without boost pump

Chorus 2+ (RO/DI/UV) Varients: 10l/hr & 20l/hr with or without boost pump

Chorus 2 (RO/DI) Varients: 10l/hr & 20l/hr with or without boost pump

Chorus 3 (RO) Varients: 10l/hr, 20l/hr & 30l/hr with or without boost pump

Specifications (Type – I)

APPLICATION PURELAB Chorus 1 PURELAB Chorus 1 Complete
Variant Life Science AnalyticalResearch General Science 10 l/hr 20 l/hr
Dispense Flowrate Up to 2.0 l/min+ Up to 2.0 l/min+ Up to 2.0 l/min+ >1.5 l/min >1.5 l/min
Inorganics @25°C 18.2 MΩ.cm 18.2 MΩ.cm 18.2 MΩ.cm 18.2 MΩ.cm 18.2 MΩ.cm
Total organic carbon (TOC) 1-3 ppb* 1-3 ppb* 3-10 ppb* <5 ppb <5 ppb
Bacteria <0.001 CFU/ml♢ <0.001 CFU/ml♢ <0.001 CFU/ml♢ <0.001 CFU/ml♢ <0.001 CFU/ml♢
Bacterial Endotoxin <0.001 EU/ml‡ <0.001 EU/ml‡ <0.001 EU/ml‡ <0.001 EU/ml‡ <0.001 EU/ml‡
pH Effectively neutral Effectively neutral Effectively neutral Effectively neutral Effectively neutral
Particles (filtration) <0.01 µm <0.05 µm 0.2 µm♢ 0.2 µm♢ 0.2 µm♢
RNase <1 pg/ml <1 pg/ml <1 pg/ml <1 pg/ml <1 pg/ml
DNase <5 pg/ml <5 pg/ml <5 pg/ml <5 pg/ml <5 pg/ml

◊ With LC134/145/197 POU filter/Biofilter

* Dependant on feed water – recommended feed <50 ppb TOC

†When connected to Halo, Advanced or flexible

‡ With LC197 Biofilter

Specifications (Type – II)

APPLICATION PURELAB Chorus 2+ (RO/EDI/UV) PURELAB Chorus 2+ (RO/DI/UV) PURELAB Chorus 2 (RO/DI)
Nominal output at 15°C 10 l/hr 20 l/hr 10 l/hr 20 l/hr 10 l/hr 20 l/hr
Nominal daily output 216 l/day 216 l/day 240 l/day 480 l/day 240 l/day 480 l/day
Inorganics @25°C 10 to >15 MΩ.cm 1 to >15 MΩ.cm 1 to >10 MΩ.cm
Organics (MW>200 Dalton) >99% rejection >99% rejection >99% rejection
Total organic carbon (TOC) <10 ppb <10 ppb <30 ppb
Bacteria <0.001 CFU/ml◊ <0.001 CFU/ml◊ <5 CFU/ml
pH Effectively neutral Effectively neutral Effectively neutral
Particles 0.2µm◊ 0.2µm◊ >99% rejection

◊With LC134/145/197 POU filter/Biofilter                            

Specifications (Type III)

APPLICATION PURELAB Chorus 3 (RO)
Nominal output at 15°C 10 l/hr 20 l/hr 30 l/hr
Nominal daily output 240 l/day 480 l/day 720 l/day
Inorganics @25°C >95% rejection
Organics (MW>200 Dalton) >95% rejection
Total organic carbon (TOC) <50 ppb
Bacteria* <50 CFU/ml
pH Effectively neutral
Particles >99% rejection

Standard conditions are 4 bar inlet pressure at 15oC, fed with potable water and a clean pre-treatment cartridge.
Refer to flow tables outside these conditions. * Bacterial specification is before the water goes into the reservoir.